Cantilever structures—balconies, weather chajjas, and grand entrance architectural canopies—are supported on only one end. Unlike ordinary simply supported slabs where the bottom steel takes tension, cantilevers experience maximum bending moment and tension on the TOP surface. Misplacing reinforcement bars at the bottom causes severe downward deflection, balcony cracks, or catastrophic collapse.

Critical Detailing Rules for Cantilever Slabs

  • Top Tension Steel Placement: Main flexural reinforcement must be located strictly in the top zone of the slab, maintained with concrete chair spacers (minimum 25mm clear cover from top).
  • Full Anchorage Length (Ld) into Inner Bay: The top bars must extend into the adjoining back span for a length equal to at least 1.5 to 2.0 times the cantilever overhang projection.
  • Down-Turned Dropped Edge Beams: Provide a rigid edge beam along the outer cantilever perimeter to distribute point live loads and anchor safety railing base plates.
  • Drainage Slope & Drip Mould: Cast the cantilever with a minimum 1:50 outward drainage slope and form a continuous 15x15mm drip groove (throating) on the underside to prevent rainwater tracking back into exterior walls.